High-Quality Household Combustible Gas Detector Shield SD6200 Series Manufacturer, Supplier

The SD6200 series household combustible gas detector (hereinafter referred to as the "detector") is a gas safety prevention product suitable for residential use. It is used to continuously detect the concentration of combustible gases indoors. When the concentration of combustible gases in the environment reaches or exceeds the alarm set value, it emits an audible and visual alarm signal and activates the solenoid valve to cut off the gas supply, preventing serious accidents such as explosions, fires, poisoning, and suffocation caused by gas leaks or incomplete combustion.

Product Description

SD6200 Front View
SHIELD SD6200 Front View
SD6200 Side View
SHIELD SD6200 Side View

Key Product Features

Optical / laser sensor offering high stability and long service life
High sensitivity with anti-interference, humidity, and heat resistance
Sound and light alarm system with automatic output linkage
Automated reminder alert for sensor end-of-life replacement
Integrated alarm history recording functionality
Compact design that is exceptionally easy to install and operate

Scope of Application

Designed specifically for residential household indoor safety and continuous combustible gas monitoring.

Technical Specifications & Parameters

Detection Principle Infrared absorption or laser-based
Detection Gas Type Methane (Natural Gas)
Detection Range Methane: 3 ~ 100% LEL
Alarm Set Value Methane: 10% LEL
Alarm Method Audible and visual alarm (Sound and light)
Response Time (T90) ≤ 30 seconds
Power Supply AC 220V ± 15% (50Hz)
Power Consumption < 3W
Detector Service Life 5 Years (Typical value)
Operating Environment Temperature: -10°C ~ +55°C | Humidity: ≤93% RH | Pressure: 86 kPa ~ 106 kPa
Storage Environment Temperature: -25°C ~ +55°C
Dimensions & Weight Diameter 90 mm × 39 mm (or 90 × 90 × 36 mm) | Approx. 115g
Enclosure Material ABS Engineering Plastic
Installation Method Wall-mounted
Communication Modes NB-IoT / 4G (Mobile phone communication alarm supported)
Optional Plugs EU / US / UK / AU / Other

Dimensions & Installation Guide

SD6200 Dimension Layout
SD6200 Product Dimensions & Layout
SD6200 Installation Diagram 1
Wall Mounting Scheme
SD6200 Installation Diagram 2
Ceiling Distance & Positioning Diagram

Unpacking & Accessories Inspection

Standard Accessories: Product Manual (1 pc), Product Certificate (1 pc), Installation Hanging Plate (1 pc), Mounting Screw Accessories (1 set).

Inspection Checklist: Ensure the device surface is free of scratches, label printing is crisp and legible, and all mounting hardware is present.

Operation & Status Indicator Guide

1. Button Operation

  • Standard Mode: Press the "Self-test" button to activate audio-visual diagnostic self-testing and trigger the linked output.
  • Alarm Condition: Press the "Self-test" button to mute the audible alarm.
  • Fault Condition: Press the "Self-check" button to silence the fault buzzer.

2. Status Indicator & Buzzer Patterns

Working Status Indicator Light Color / Pattern Buzzer Behavior
Normal State Green Flash Silent
Fault State Yellow Solid Intermittent chirping
Alarm State Red Solid Rapid chirping
End of Life Yellow Flashing Silent
Power-On Self-Test Indicators flash sequentially for 10 seconds before entering regular operation Beeps once upon completion, then transitions to normal mode
Manual Self-Check Flashes cyclically for 10 seconds while initiating linkage output Continuous beeping during the test duration

Frequently Asked Questions (FAQ)

What gas does the SHIELD SD6200 detect, and what is its trigger point?

The SHIELD SD6200 is engineered to detect Methane (natural gas). It has an effective detection range of 3% to 100% LEL and sets off its audible and visual alarm when gas concentration reaches 10% LEL.

What sensing technology is utilized, and how long does the sensor last?

The detector incorporates optical / laser sensor technology based on infrared absorption. Both the detector unit and its integrated sensor feature a typical operational service life of 5 years.

How do I know when the detector has reached the end of its service life?

The SD6200 is built with an automatic end-of-life reminder. When the device reaches the end of its operating lifespan, the indicator light flashes yellow continuously while remaining silent.

How do the button functions work during alarms or routine testing?

Under normal operating conditions, pressing the self-test button triggers an audio-visual functional check and activates linkage output. If the detector is currently alarming or signaling a fault, pressing the same button mutes the buzzer.

What environmental conditions are suitable for running the SD6200?

The recommended operating temperature range is -10°C to +55°C with a relative humidity of ≤93% RH and atmospheric pressure between 86 kPa and 106 kPa. For non-operating storage, temperatures between -25°C and +55°C are supported.

What accessories and mounting options are provided in the box?

Each unit includes an installation hanging plate and a screw kit designed for wall-mounted installation, accompanied by a product manual and inspection certificate.