ODM Industrial and Commercial Gas Detector Shield SD2100A Series Manufacturer, Factory

Product Overview

 

The GTYQ-SD2100A series point-type gas detector (hereinafter referred to as the detector) is an intelligent bus and branch line product. It forms a gas alarm detection system with the matching controller to conduct real-time detection of target gases that may be present in the working environment. It displays the real-time concentration of the gas on-site, and when the concentration exceeds the limit, the controller issues an audible and visual alarm signal. The controller can monitor the normal, fault, or alarm status of the detector, and can also use the controller or remote control to perform zero point calibration, concentration calibration, and set parameters such as high/low alarm limits.

 

Application

 

This leak detector is widely used in the petroleum, chemical, environmental protection, metallurgy, refining, gas distribution, biochemical medicine, and agriculture industries

Product Description

Description
2100-Afront-1
Product Features
Compatible with bus systems and 4-20mA distributed systems, facilitating system design and expansion.
Infrared remote control operation, no need to open the cover for on-site operation.
Three independent indicator lights, indicating normal operation/fault/alarm of the device.
Comes with linkage control output, capable of controlling on-site sound and light or fan/valve.
Dual outlet structure, convenient for on-site construction.
Built-in temperature detection function ensures accurate and effective detection of the product in various temperature environments.
2100-ASide-view-2
Unboxing and Inspection
Standard accessories: Product manual (1 piece), factory inspection report (1 piece), product certificate (1 piece), mounting bracket (1 piece), installation accessories (1 piece).
Unboxing inspection: The product appearance has no scratches, the label is intact and clear, and the accessories are complete.
Technical Parameters
Detected gasesMethane/Propane/Other gases
Detection principleCatalytic combustion/semiconductor
Sampling methodDiffusion type
Measurement range(3~100)%LEL or others
Alarm set point (default for combustible gas)Low limit 25% LEL   High limit 50% LEL
Alarm error±3% F.S
Response timeCombustible gas ≤30s (T90)
Power Consumption≤3W (DC24V)
Protection levelIP66
Explosion-proof ratingExdb IIC T6 Gb
Communication methodS-BUS bus & 4-20mA point-to-point system
External control output1 switch signal, default active output DC24V/30mA
Sensor lifespanThree years (typical for catalytic)
Storage environmentTemperature 0℃~+35℃, relative humidity 25%RH~70%RH
Operating environmentTemperature -40℃ to +70℃, relative humidity ≤93%RH, ambient atmospheric pressure 86kPa to 106kPa
Explosion-proof cable entry interfaceOuter diameter of the wire 9-10mm
Threaded interface sizeG3/4
Product weightApproximately 733g
Product dimensions150mm×135mm×66.5mm
Installation and Wiring
Installation Diagram (Dimensions: mm)
Mounting Plate (Dimensions: mm)
Industrial and Commercial Gas Detector Shield SD2100A Series (1)
Terminal Diagram and Description
Industrial-and-Commercial-Gas-Detector-Shield-SD2100A-Series-(2)_03
Detector Wiring Diagram:
Detector terminal Terminal description Remarks
24V+ DC 24V power positive
GND DC 24V power negative
S+ S-BUS bus signal positive
S- S-BUS bus signal negative
SI 4-20mA signal output
CM1 "Continuous output" The default active output is DC24V/30mA.
NO1
Frequently Asked Questions
Q What gases can this detector measure?
The detector is designed for combustible gases such as Methane and Propane, utilizing catalytic combustion or semiconductor sensors for accurate detection.
Q How does the device support calibration and adjustment without opening the casing?
It features an infrared remote control operation design, enabling full on-site setup and adjustments without needing to open the explosion-proof enclosure.
Q What communication and output interfaces are supported?
The system supports both S-BUS communication and a standard 4-20mA point-to-point output, as well as an active DC24V/30mA relay control output for sirens, fans, or valves.
Q What is the ingress and explosion-proof rating of the enclosure?
It offers an IP66 ingress protection rating and an Exdb IIC T6 Gb explosion-proof certification, making it suitable for harsh and demanding industrial environments.
Q What is the typical lifespan of the catalytic sensor?
Under normal operating conditions, the typical service lifespan of the catalytic sensor is approximately three years.
Q What are the default alarm thresholds configured on the device?
The factory default settings for combustible gas monitoring are configured at a low alarm limit of 25% LEL and a high alarm limit of 50% LEL.

Related Products

Compare 0/3
Get Comparison Datasheets