1 / 2
ODM Industrial and Commercial Gas Detector Shield SD2100A Series Manufacturer, Factory
Product Description
Description
Product Features
Compatible with bus systems and 4-20mA distributed systems, facilitating system design and expansion.
Infrared remote control operation, no need to open the cover for on-site operation.
Three independent indicator lights, indicating normal operation/fault/alarm of the device.
Comes with linkage control output, capable of controlling on-site sound and light or fan/valve.
Dual outlet structure, convenient for on-site construction.
Built-in temperature detection function ensures accurate and effective detection of the product in various temperature environments.
Unboxing and Inspection
Standard accessories: Product manual (1 piece), factory inspection report (1 piece), product certificate (1 piece), mounting bracket (1 piece), installation accessories (1 piece).
Unboxing inspection: The product appearance has no scratches, the label is intact and clear, and the accessories are complete.
Technical Parameters
| Detected gases | Methane/Propane/Other gases |
| Detection principle | Catalytic combustion/semiconductor |
| Sampling method | Diffusion type |
| Measurement range | (3~100)%LEL or others |
| Alarm set point (default for combustible gas) | Low limit 25% LEL High limit 50% LEL |
| Alarm error | ±3% F.S |
| Response time | Combustible gas ≤30s (T90) |
| Power Consumption | ≤3W (DC24V) |
| Protection level | IP66 |
| Explosion-proof rating | Exdb IIC T6 Gb |
| Communication method | S-BUS bus & 4-20mA point-to-point system |
| External control output | 1 switch signal, default active output DC24V/30mA |
| Sensor lifespan | Three years (typical for catalytic) |
| Storage environment | Temperature 0℃~+35℃, relative humidity 25%RH~70%RH |
| Operating environment | Temperature -40℃ to +70℃, relative humidity ≤93%RH, ambient atmospheric pressure 86kPa to 106kPa |
| Explosion-proof cable entry interface | Outer diameter of the wire 9-10mm |
| Threaded interface size | G3/4 |
| Product weight | Approximately 733g |
| Product dimensions | 150mm×135mm×66.5mm |
Installation and Wiring
Installation Diagram (Dimensions: mm)
Mounting Plate (Dimensions: mm)
Terminal Diagram and Description
Detector Wiring Diagram:
| Detector terminal | Terminal description | Remarks |
|---|---|---|
| 24V+ | DC 24V power positive | |
| GND | DC 24V power negative | |
| S+ | S-BUS bus signal positive | |
| S- | S-BUS bus signal negative | |
| SI | 4-20mA signal output | |
| CM1 | "Continuous output" | The default active output is DC24V/30mA. |
| NO1 |
Frequently Asked Questions
Q What gases can this detector measure?
The detector is designed for combustible gases such as Methane and Propane, utilizing catalytic combustion or semiconductor sensors for accurate detection.
Q How does the device support calibration and adjustment without opening the casing?
It features an infrared remote control operation design, enabling full on-site setup and adjustments without needing to open the explosion-proof enclosure.
Q What communication and output interfaces are supported?
The system supports both S-BUS communication and a standard 4-20mA point-to-point output, as well as an active DC24V/30mA relay control output for sirens, fans, or valves.
Q What is the ingress and explosion-proof rating of the enclosure?
It offers an IP66 ingress protection rating and an Exdb IIC T6 Gb explosion-proof certification, making it suitable for harsh and demanding industrial environments.
Q What is the typical lifespan of the catalytic sensor?
Under normal operating conditions, the typical service lifespan of the catalytic sensor is approximately three years.
Q What are the default alarm thresholds configured on the device?
The factory default settings for combustible gas monitoring are configured at a low alarm limit of 25% LEL and a high alarm limit of 50% LEL.